Skip to content
Commit cd1d9961 authored by Ondrej Zajicek (work)'s avatar Ondrej Zajicek (work)
Browse files

BGP: Shutdown communication (RFC 8203)

The patch implements BGP Administrative Shutdown Communication (RFC 8203)
allowing BGP operators to pass messages related to BGP session
administrative shutdown/restart. It handles both transmit and receive of
shutdown messages. Messages are logged and may be displayed by show
protocol all command.

Thanks to Job Snijders for the basic patch.