Bluetooth: controller: Prevent invalid compiler code reordering
In ull_disable, it is imperative that the callback is set up before a second reference counter check, otherwise it may happen that an LLL done event has already passed when the disable callback and semaphore is assigned. This causes the HCI thread to wait until timeout and assert after ull_ticker_stop_with_mark. For certain compilers, due to compiler optimizations, it can be seen from the assembler code that the callback is assigned after the second reference counter check. By adding memory barriers, the code correctly reorders code to the expected sequence. Signed-off-by:Morten Priess <mtpr@oticon.com> (cherry picked from commit 7f82b6a2) Signed-off-by:
Vinayak Kariappa Chettimada <vich@nordicsemi.no>