drivers: adc: stm32: do not disable adc after measurement



Do not disable the ADC after the end of the measurement to avoid systematic
enabling which is time-consuming in case the configuration is unchanged.

Signed-off-by: default avatarGuillaume Gautier <guillaume.gautier-ext@st.com>
(cherry picked from commit 62f11055)